Sometimes if the model is incorrectly classified the approval number is not correct.
NOTE: This should only be done if it is issue 1 of the project.
Example a Fixed wing Aircraft (A) was entered as a Helicopter (H) or an Engine (E).
You will need to use System Tables to clear out the Certificate Number.
First search the MOD_PROJ table for the matching project number.
Open the Project detail and Make a note of the MOD_ID_NUM
Then Search in system tables Mod Project Revision (MOD_APRV_RVS) for that matching MOD_ID_NUM
(You should only get 1 Project since it is issue1)
Open the List and detail
Delete the value in Aprv_num and save the record
Go back to regular NAPA Search and search the Project the regular way.
Open the Project Detail Certificate Summary tab and use the get Approval Number button to generate the correct approval number. Save the project.